General Purpose Low Voltage Transformers

Reliable and Efficient Power

MGM Transformers’ Low Voltage (600V Class) Dry-Type General Purpose Transformers deliver dependable, efficient power for a wide range of commercial and industrial applications. Stocked in over 20 major cities across the continental U.S., these units are readily available to support fast-moving project timelines with proven reliability and performance.

In addition to our stocked offering, MGM specializes in custom-engineered solutions tailored to unique application requirements. Whether you need non-standard voltage combinations, specialized tap arrangements, unique winding configurations, or custom enclosures, our team of 50+ engineers can design and build transformers to align precisely with your operational needs.

All units are built with industry-leading features to ensure safety, durability, and efficiency, backed by our vertically integrated manufacturing process and stringent quality controls.

Looking for a medium voltage option? Click Here

KEY Features:

  • DOE 2016 Efficiency Compliant: Designed to meet modern energy standards for lower operating costs.
  • Certified for Safety and Durability: UL 506 and UL 1561 Listed, with seismic certification per ASCE/SEI 7-05 and OSHPD OSP Pre Approval.
  • Voltage Configurations: Any voltage combination to suit your system requirements.
  • Winding: Available with aluminum or copper windings to suit your needs.
  • Frequency: Available with 50, 60 or 50/60 Hz
  • Enclosure Types: Options include NEMA 1, 3R, 4, 4X, and more to match environmental conditions.
  • Special Applications: Designs for low-noise environments, marine duty, solar duty, totally enclosed non-ventilated (TENV) settings, autotransformers, and OSHPD-certified enclosures.

Why Choose MGM Transformers?

  • Nationwide Availability: Stocked in 20 major cities for fast delivery.
  • Reliable Performance: Engineered to provide consistent power for critical loads.
  • Durable and Certified: Built to meet seismic and safety standards.
  • Energy Efficient: Designed to reduce energy losses and comply with DOE standards.


STANDARD FEATURES

  • DOE 2016 Efficiency Compliant
  • UL 506, UL 1561 Listed
  • Aluminum or Copper Windings
  • 60 Hz
  • Electrostatic Shield
  • 150°C Temperature Rise
  • Seismically Certified per ASCE/SEI 7-05
  • OSHPD OSP Pre Approval

SOUND LEVELS

600 Volt class general purpose dry type transformers designed to meet NEMA ST-20 sound levels.

ACCESSORIES

  • Seismic Kits
  • Wall Brackets
  • Rodent Screens
  • Weathershield Kits

TESTING AND QUALITY ASSURANCE

As part of MGM Transformers’ quality assurance process, all 600 Volt transformers go through a rigorous IEEE test plan to ensure optimum performance. These tests include:

  • Winding resistance test
  • Turns ratio test
  • Polarity and phase relation test
  • No load losses and exciting current test
  • Impedance and load loss test
  • Applied potential test

ENCLOSURES

Ventilated transformers utilize a NEMA 2 rated drip proof metal enclosure with natural draft ventilation. MGM Transformers’ dual rated enclosures are suitable for indoor or outdoor applications and are standard on all models except the 225, 300, and 500 kVA transformers (optional Weather-shield Kits are available for these units).

VOLTAGE TAPS

Taps will compensate for the high or low line voltages. MGM Transformers’ 600 Volt class transformers are provided with 6 primary taps:

  • 2 taps @ 2-1/2% FCAN
  • 4 taps @ 2-1/2% FCBN
480 – 208/120 | 60 HZ, 150ºC, 3 PHASE, ALUMINUM​
CAT #
ALT #
RATING
H (in)
W (in)
D (in)
WEIGHT (lbs)
DIMS DWG
15YS*D16
15 KVA
28
21
14
235
A
30YS*D16
30 KVA
32
26.5
17
355
B
45YS*D16
45 KVA
32
26.5
17
425
B
75YS*D16
75 KVA
38.5
28.5
20
595
B+
112YS*D16
112.5 KVA
40.5
31.5
21.75
795
C
150YS*D16
150 KVA
40.5
36.5
21.75
1,020
C+
225YS*D16
225 KVA
51.5
40.5
26.5
1,580
D
300YS*D16
300 KVA
51.5
40.5
26.5
1,875
D
500YS*D16
500 KVA
66
50.5
32
3,295
E
HT750A3B2-D16
750YS*D16
750 KVA
80.25
64
50
3,850
F
480 – 240/120ct | 60 HZ, 150ºC, 3 PHASE, ALUMINUM
CAT #
ALT #
RATING
H (in)
W (in)
D (in)
WEIGHT (lbs)
DIMS DWG
15DS*D16
15 KVA
28
21
14
240
A
30DS*D16
30 KVA
32
26.5
17
355
B
45DS*D16
45 KVA
32
26.5
17
425
B
75DS*D16
75 KVA
38.5
28.5
20
590
B+
112DS*D16
112.5 KVA
40.5
31.5
21.75
790
C
150DS*D16
150 KVA
40.5
36.5
21.75
1,015
C+
225DS*D16
225 KVA
51.5
40.5
26.5
1,570
D
300DS*D16
300 KVA
51.5
40.5
26.5
1,865
D
500DS*D16
500 KVA
66
50.5
32
3,215
E
240 – 208/120 | 60 Hz, 150ºC, 3 PHASE, ALUMINUM
CAT #
ALT #
RATING
H (in)
W (in)
D (in)
WEIGHT (lbs)
DIMS DWG
15CS*D16
15 KVA
28
21
14
235
A
30CS*D16
30 KVA
32
26.5
17
355
B
45CS*D16
45 KVA
32
26.5
17
425
B
75CS*D16
75 KVA
38.5
28.5
20
595
B+
112CS*D16
112.5 KVA
40.5
31.5
21.75
795
C
150CS*D16
150 KVA
40.5
36.5
21.75
1,010
C+
240X480 – 120/240 | 60 Hz, 150ºC, 1 PHASE, ALUMINUM
CAT #
ALT #
RATING
H (in)
W (in)
D (in)
WEIGHT (lbs)
DIMS DWG
10SS*D16
10 KVA
28
21
14
175
A
15SS*D16
15 KVA
28
21
14
205
A
25SS*D16
25 KVA
32
26.5
17
270
B
37SS*D16
37.5 KVA
32
26.5
17
345
B
50SS*D16
50 KVA
32
26.5
17
385
B
75SS*D16
75 KVA
38.5
28.5
20
530
B+
100SS*D16
100KVA
40.5
31.5
21.75
620
C
480V DELTA PRIMARY-480y/277, 60 Hz, 150°C, 3 PHASE, ALUMINUM
CAT #
Alt #
Rating
H (in)
W (in)
D (in)
WEIGHT (lbs)
DIMS DWG
15AD*D16
15 KVA
28
21
14
240
A
30AD*D16
30 KVA
32
26.5
17
355
B
45AD*D16
45 KVA
32
26.5
17
425
B
75AD*D16
75 KVA
38.5
28.5
20
590
B+
112AD*D16
112.5 KVA
40.5
31.5
21.75
790
C
150AD*D16
150 KVA
40.5
36.5
21.75
1015
C+
HT225A3D2-D16
225AD*D16
225 KVA
51.5
40.5
26.5
1570
D
HT300A3D2-D16
300AD*D16
300 KVA
51.5
40.5
26.5
1865
D
HT500A3D2-D16
500AD*D16
500 KVA
66.0
50.5
32.0
3215
E
208V DELTA PRIMARY-480y/277, 60 Hz, 150°C, 3 PHASE, ALUMINUM
CAT #
Alt #
Rating
H (in)
W (in)
D (in)
Weight (lbs)
DIMS DWG
15GD*D16
15 KVA
28
21
14
240
A
30GD*D16
30 KVA
32
26.5
17
355
B
45GD*D16
45 KVA
32
26.5
17
425
B
75GD*D16
75 KVA
38.5
28.5
20
590
B+
112GD*D16
112.5 KVA
40.5
31.5
21.75
790
C
150GD*D16
150 KVA
40.5
36.5
21.75
1015
C+
HT225G3D2-D16
225GD*D16
225 KVA
51.5
40.5
26.5
1570
D
HT300G3D2-D16
300GD*D16
300 KVA
51.5
40.5
26.5
1865
D
HT500G3D2-D16
500GD*D16
500 KVA
66.0
50.5
32.0
3215
E
240V DELTA PRIMARY-480y/277, 60 Hz, 150°C, 3 PHASE, ALUMINUM
CAT #
Alt #
Rating
H (in)
W (in)
D (in)
Weight (lbs)
DIMS DWG
15CD*D16
15 KVA
28
21
14
240
A
30CD*D16
30 KVA
32
26.5
17
355
B
45CD*D16
45 KVA
32
26.5
17
425
B
75CD*D16
75 KVA
38.5
28.5
20
590
B+
112CD*D16
112.5 KVA
40.5
31.5
21.75
790
C
150CD*D16
150 KVA
40.5
36.5
21.75
1015
C+
HT225C3D2-D16
225CD*D16
225 KVA
51.5
40.5
26.5
1570
D
HT300C3D2-D16
300CD*D16
300 KVA
51.5
40.5
26.5
1865
D
HT500C3D2-D16
500CD*D16
500 KVA
66.0
50.5
32.0
3215
E
208V DELTA PRIMARY – 120/208, 60 Hz, 150°C, 3 PHASE, ALUMINUM
CAT #
Alt #
Rating
H (in)
W (in)
D (in)
Weight (lbs)
DIMS DWG
15GB*D16
15 KVA
28
21
14
240
A
30GB*D16
30 KVA
32
26.5
17
355
B
45GB*D16
45 KVA
32
26.5
17
425
B
75GB*D16
75 KVA
38.5
28.5
20
590
B+
112GB*D16
112.5 KVA
40.5
31.5
21.75
790
C
150GB*D16
150 KVA
40.5
36.5
21.75
1015
C+
HT225G3B2-D16
225GB*D16
225 KVA
51.5
40.5
26.5
1570
D
HT300G3B2-D16
300GB*D16
300 KVA
51.5
40.5
26.5
1865
D
HT500G3B2-D16
500GB*D16
500 KVA
66.0
50.5
32.0
3215
E
480 – 208/120 | 60 HZ, 150ºC, 3 PHASE, COPPER
CAT #
ALT #
RATING
H (in)
W (in)
D (in)
WEIGHT (lbs)
DIMS DWG
15YSC*D16
15 KVA
28
21
14
231
A
30YSC*D16
30 KVA
32
26.5
17
340
B
45YSC*D16
45 KVA
32
26.5
17
418
B
75YSC*D16
75 KVA
38.5
28.5
20
599
B+
112YSC*D16
112.5 KVA
40.5
31.5
21.75
806
C
150YSC*D16
150 KVA
40.5
36.5
21.75
942
C+
225YSC*D16
225 KVA
51.5
40.5
26.5
1,755
D
300YSC*D16
300 KVA
51.5
40.5
26.5
2,068
D
500YSC*D16
500 KVA
66
50.5
32
3,382
E
480 – 240/120 | 60 HZ, 150ºC, 3 PHASE, COPPER
CAT #
Alt #
Rating
H (in)
W (in)
D (in)
Weight (lbs)
Case
15DSC*D16
15 KVA
28
21
14
250
A
30DSC*D16
30 KVA
32
26.5
17
370
B
45DSC*D16
45 KVA
32
26.5
17
455
B
75DSC*D16
75 KVA
38.5
28.5
20
645
B+
112DSC*D16
112 KVA
40.5
31.5
22
840
C
150DSC*D16
150 KVA
40.5
36.5
21.75
1045
C+
225DSC*D16
225 KVA
51.5
40.5
26.5
1720
D
300DSC*D16
300 KVA
51.5
40.5
26.5
1940
D
500DSC*D16
500 KVA
66
50.5
32
3425
E
What is a general purpose dry-type transformer and what is it used for?

A general purpose dry-type transformer is a low-voltage transformer that uses air as its cooling medium instead of oil, making it safe for indoor installation without the need for a containment vault or fire suppression system. It steps voltage up or down within the 600V class to match the power requirements of connected equipment. These transformers are widely used in commercial buildings, schools, hospitals, manufacturing facilities, retail centers, and industrial plants to distribute power reliably from the utility feed to lighting, HVAC systems, motor controls, panel boards, and general electrical loads.

What kVA sizes are available in stocked general purpose transformer range?

Our stocked general purpose low-voltage transformers are available in ratings from 15 kVA up to 750 kVA for three-phase units, and from 10 kVA up to 100 kVA for single-phase units. Common three-phase sizes include 15, 30, 45, 75, 112.5, 150, 225, 300, 500, and 750 kVA. For projects requiring ratings outside these sizes, MGM also offers custom-engineered builds through their general purpose custom program.

What voltage configurations are available?

We stock transformers in the most common North American voltage combinations, including 480V to 208/120V three-phase, 480V to 240/120V three-phase, 240V to 208/120V three-phase, 480V delta primary to 480Y/277V three-phase, 208V delta primary to 480Y/277V three-phase, 240V delta primary to 480Y/277V three-phase, 208V delta primary to 120/208V three-phase, and 240X480V to 120/240V single-phase. Custom voltage combinations are available for projects with non-standard requirements.

What is the difference between aluminum and copper winding transformers, and which should I choose?

Both aluminum and copper winding options are available across our stocked product range. For most standard commercial and light industrial applications in controlled indoor environments, aluminum windings are the more common and cost-effective choice. Copper windings are often specified for marine, coastal, or high-humidity environments, or when the project specification explicitly requires copper.

Contact us directly if you are unsure which winding material is appropriate for your specific application and installation conditions.

What enclosure types are available and how do I choose the right one?

Our general purpose transformers are available with NEMA 1, 3R, 4, and 4X enclosure ratings. NEMA 1 is a standard ventilated indoor enclosure suitable for clean, dry indoor locations. The standard stocked enclosure on most models is a NEMA 2 rated drip-proof ventilated metal enclosure with natural draft ventilation, which is dual-rated for indoor or outdoor use. NEMA 3R provides protection against rain for outdoor installations. NEMA 4 and 4X provide watertight and corrosion-resistant protection for washdown or harsh outdoor environments, with 4X adding stainless steel construction for chemical or marine applications. Note that 225, 300, and 500 kVA units are indoor-rated as standard and require an optional Weathershield Kit for outdoor installation.

What certifications and standards do these transformers meet?

Our general purpose low-voltage transformers are UL 506 and UL 1561 Listed and are DOE 2016 efficiency compliant, meeting the federal minimum efficiency standards for distribution transformers. Seismic certification per ASCE/SEI 7-05 with OSHPD OSP Pre-Approval is standard on all units, making them eligible for installation in California hospitals and other facilities with strict seismic requirements. Sound levels are designed to meet NEMA ST-20 standards. All units go through a rigorous IEEE test plan during production, which includes winding resistance, turns ratio, polarity and phase relation, no-load losses and exciting current, impedance and load loss, and applied potential testing.

What voltage taps are provided and why do they matter?

Our 600V class transformers come standard with 6 primary voltage taps: 2 taps at 2.5% full capacity above normal (FCAN) and 4 taps at 2.5% full capacity below normal (FCBN). Voltage taps allow the installer to fine-tune the transformer’s output voltage to compensate for variations in the incoming line voltage at the installation site. If the supply voltage runs consistently high or low relative to the nominal rating, the appropriate tap can be selected to bring the secondary output voltage into the correct range for the connected equipment. Tap adjustments are made on the de-energized primary winding and require the transformer to be shut down before any tap position is changed.

Where are your general purpose transformers stocked and how quickly can they be delivered?

We stock these transformers in over 20 major cities across the continental United States, which means most standard configurations can ship quickly without the delays associated with custom manufacturing. For emergency situations where a transformer needs to be sourced and delivered immediately due to a field failure or critical project deadline, our Bull Rush program provides 24/7 emergency production and delivery support with a money-back guarantee.

Can these transformers be used in special or non-standard applications?

Yes. While the stocked range covers the most common commercial and industrial applications, we also offer custom-engineered variants for special duty requirements. These include low-noise designs for sound-sensitive environments such as hospitals or offices, marine duty units for high-humidity and salt air environments, solar duty configurations, totally enclosed non-ventilated (TENV) designs for dirty or contaminated environments where ventilation openings are not acceptable, and autotransformer configurations. Custom enclosures, non-standard frequency options including 50 Hz and 50/60 Hz dual-rated, and non-standard voltage combinations are all available through our customization options. Submit a quote with your specifications.

Contact Us

Bull Rush

Emergencies happen and we’re here to respond. We will work 24/7 till the emergency transformer is done or your money back!